Repository logo
 

Investigation of Hornyak Fast Neutron Detector

dc.contributor.authorSchafer, G. J.
dc.date.accessioned2012-01-31T01:20:18Z
dc.date.accessioned2022-11-01T01:49:53Z
dc.date.available2012-01-31T01:20:18Z
dc.date.available2022-11-01T01:49:53Z
dc.date.copyright1954
dc.date.issued1954
dc.description.abstractThis work is a theoretical and experimental investigation of the Hornyak fast neutron detector. The detector consists of a lucite and ZnS moulded cylinder used in conjunction with an EMI 5045 photomultiplier tube. Formulae for the efficiency of single-ended and coincidence setups have been derived and used to predict the most efficient arrangements. The formula for a single ended arrangement has been shown to agree with experiment. It was found that in spite of lower efficiency, a coincidence setup has certain advantages for particular applications.en_NZ
dc.formatpdfen_NZ
dc.identifier.urihttps://ir.wgtn.ac.nz/handle/123456789/27609
dc.languageen_NZ
dc.language.isoen_NZ
dc.publisherTe Herenga Waka—Victoria University of Wellingtonen_NZ
dc.subjectRadioactivity
dc.subjectPhysics
dc.titleInvestigation of Hornyak Fast Neutron Detectoren_NZ
dc.typeTexten_NZ
thesis.degree.grantorTe Herenga Waka—Victoria University of Wellingtonen_NZ
thesis.degree.levelMastersen_NZ
thesis.degree.nameMaster of Scienceen_NZ