DSpace Repository

Parameter Space Mapping for Blood Oxygenation Measurement with Low Field NMR

Show simple item record

dc.contributor.advisor Obruchkov, Sergei
dc.contributor.advisor Galvosas, Petrik
dc.contributor.advisor Tzeng, Shieak
dc.contributor.author Thomas, Dion Gary
dc.date.accessioned 2018-11-21T03:20:41Z
dc.date.accessioned 2022-11-03T21:12:03Z
dc.date.available 2018-11-21T03:20:41Z
dc.date.available 2022-11-03T21:12:03Z
dc.date.copyright 2018
dc.date.issued 2018
dc.identifier.uri https://ir.wgtn.ac.nz/handle/123456789/30161
dc.description.abstract Blood oxygenation is a critical physiological parameter for patient health. The clinical importance of this parameter means that measurement of blood oxygenation is a routine part of care. Magnetic resonance provides a way to measure blood oxygenation through the paramagnetic effect of deoxy-haemoglobin, which decreases the T2 relaxation time of blood. This effect has been well characterised at high fields (>1:5 T) for use in Magnetic Resonance Imaging, and it is a contributing factor to the Blood Oxygenation Level Dependent contrast used in functional MRI. However there are relatively few studies of this effect at low magnetic fields, and these have only looked at extreme levels of oxygenation/deoxygenation. To study this effect for potential application in a low-field device, we measured this effect to determine how factors such as oxygenation, field strength and CPMG echo time affect the T2 of blood. A continuous flow circuit, similar to a cardiopulmonary bypass circuit, was used to control parameters such as oxygen saturation and temperature, before the blood sample flowed into a variable field magnet (set at fields between 5-40 MHz), where a series of CPMG experiments with echo times ranging from 1 ms to 20 ms were performed to measure the T2. Additionally, the oxygen saturation was continually monitored by an optical sensor, for comparison with the T2 changes. This allowed us to test the sensitivity of this effect at low fields. These results show that at low fields, the T2 relaxation change still follows the trends shown in the literature, with a dependence on B0 squared, and on the fraction of deoxyhaemoglobin squared. Additionally, these results were also compared with two theoretical models for the dependence on echo time, which have previously been tested at high fields: the Luz-Meiboom equation, and the Jensen and Chandra model. Both models gave good agreement with the data measured at low fields. These experiments show that the T2 changes in blood due to oxygenation are still visible at low field, and that this technique should be feasible in a low field device. en_NZ
dc.format pdf en_NZ
dc.language en_NZ
dc.language.iso en_NZ
dc.publisher Te Herenga Waka—Victoria University of Wellington en_NZ
dc.subject NMR en_NZ
dc.subject Nuclear Magnetic Resonance en_NZ
dc.subject Oxygenation en_NZ
dc.subject Relaxometry en_NZ
dc.title Parameter Space Mapping for Blood Oxygenation Measurement with Low Field NMR en_NZ
dc.type Text en_NZ
vuwschema.contributor.unit School of Chemical and Physical Sciences en_NZ
vuwschema.subject.anzsrcfor 020699 Quantum Physics not elsewhere classified en_NZ
vuwschema.subject.anzsrcseo 970102 Expanding Knowledge in the Physical Sciences en_NZ
vuwschema.type.vuw Awarded Research Masters Thesis en_NZ
thesis.degree.discipline Physics en_NZ
thesis.degree.grantor Te Herenga Waka—Victoria University of Wellington en_NZ
thesis.degree.level Masters en_NZ
thesis.degree.name Master of Science en_NZ


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account